MARC details
000 -LEADER |
fixed length control field |
02493nam a22002297a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
UPMIN |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20250213094114.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
250213b |||||||| |||| 00| 0 eng d |
040 ## - CATALOGING SOURCE |
Transcribing agency |
UPMin |
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
LG993.5 2023 |
Local cutter number (OCLC) ; Book number/undivided call number, CALL (RLIN) |
A7 T83 |
100 ## - MAIN ENTRY--PERSONAL NAME |
Personal name |
Tubidan, Glynry L. |
9 (RLIN) |
26849 |
245 ## - TITLE STATEMENT |
Title |
Comparative assessment of the outdoor thermal environment and evaluation of urban heat island mitigation strategies for urban areas in poblacion district, Davao City / |
Statement of responsibility, etc. |
Glynry L. Tubidan; Myrafe S. Ylagan, adviser |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Date of publication, distribution, etc. |
2023 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
317 leaves |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis |
Degree type |
(BS Architecture) |
Name of granting institution |
University of the Philippines Mindanao, |
Year degree granted |
2023 |
520 3# - SUMMARY, ETC. |
Summary, etc. |
Due to the alarming rate of urbanization in Davao City’s Central Business District, the outdoor thermal environment is compromised. This phenomenon is accompanied by the occurrence of urban heat islands (UHI). The first objective of the study is to evaluate the existing outdoor thermal environment of urban areas in the Poblacion District where there are six study sites selected. Among all the sites, Site 6 (City Hall Complex)has the highest THI value (average THI=26.81°C, peaks at 4:00pm=30.63°C). Site 6 was then chosen as a control variable (SC0) for Scenario Simulation which covers the second objective is to determine how to improve the existing outdoor thermal environment of these areas by incorporating various mitigation strategies. All these are made possible through 3D simulation using the ENVI-met software. <br/>Among the individual scenarios tested, SC2 which involves improvement of material albedo averaged the highest THI difference (0.37°C; range=0.07°C - 0.83°C), followed by SC1 which involves improvement in vegetation (0.29°C; range=0.08°C - 0.74°C). Lastly, SC3 involving green roofs has the least average THI difference (0.29°C; range=0.08°C - 0.74°C) denoting that this mitigation strategy is substantially less effective compared to the other two scenarios. Among the all combination scenarios tested, the SC5 which combines all the mitigation strategies has the best result (0.67°C; range=0.24°C - 1.33°C). SC4 that involves mitigation strategies from SC1 and SC2 also showed a great result (0.47°C; range=0.07°C - 0.99°C). |
658 ## - INDEX TERM--CURRICULUM OBJECTIVE |
Main curriculum objective |
Architectural Research Design IX: Project Research in Architecture |
Curriculum code |
ARCH191 |
658 ## - INDEX TERM--CURRICULUM OBJECTIVE |
Main curriculum objective |
Architectural Design X: Architectural Design Project |
Curriculum code |
ARCH192 |
700 ## - ADDED ENTRY--PERSONAL NAME |
Personal name |
Ylagan, Myrafe S. |
Relator term |
adviser |
9 (RLIN) |
25472 |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
a |
UP |
-- |
Fi |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Library of Congress Classification |
Koha item type |
Thesis |
Suppress in OPAC |
No |